The Difference of APP Plasma Technology 1. Direct plasma guarantees faster, better treatments. 2. Lower gas consumptions means lower costs. AR vs N2 7.000 Liter x 5EA Gas consumption per month, Standard 100mm Length of the plasma head: 200mmConversion rate (Liquid/Gas)Ar Gas: 1L / 840LN2 Gas: 1L / 700L3. Cost per litre (quote from Supplier P)Time of operation per month: 6000 minutes (60 minutes * 20 hours * 30 days / 6, 6 = 30 seconds / 5 seconds) 3. No suction system is required because the side production level of noxious gases (ozone, NOx) is near zero. * Performance test Model : MD-150 (3Kit)1) Test for ozone production Test itemSTANDARDResult 8hours averageMust be less than 0.04 ppm 0,008 ppmMaximumMust be less than 0.04 ppm 0,012 ppm 2) Test for NOx production Test itemSTANDARDResult 8 hours averageMust be less than 0.04 ppm 0,02 ppmMaximumMust be less than 0.04 ppm 0,02 ppm 4. No effect of surface treatment except plasma contact Plasma treatment surface (Front) ① : Dyne(60) Test result: Ink spreads on the surface Contact angle 10.7˚ Plasma treatment surface (Backside) ② : Dyne(60) Testresult: Ink gets together ④ : Contact angle 42.6˚ ◎ Working Distance : 6mm ◎ Treatment Speed : 60mm/sec 5. No Particle *Model : MD-200 Particle measurement results Plasma Type (Company)Experimental conditionsNo of particles seeds(0.3 um↑/minutes)RemarkAr Plasma (APP)Plasma “Off”Gas (Ar) “On”1.5–Plasma “On”Gas (Ar) “On”3.51.5 → 3.5 (2increased)He Plasma(APP)Plasma “Off”Gas (He) “On”2.2–Plasma “On”Gas (He) “On”1.82.2 → 1.8 (no increase)N2 PlasmaOther companyPlasma “Off”Gas (N2+CDA) “On”14–Plasma “On”Gas (N2+CDA) “On”40814 → 408 (394increased) 6. Superior performance in removing static electricity Before plasma treatment After plasma treatment Removing static electricity through module itself ground Hundreds times of removing effect more than Ionizer 7. Safe and power consumption reduction using low-voltage plasma 1/10 compared to other companies 8. Excellent durability Low Voltage (Direct Plasma) - APPHigh voltage (Remote plasma) Small sputtering phenomenon by small ion accelerationBig ion acceleration and particle generated because of sputtering phenomenonBo bleaching for quartz and general ceramicsSpecial ceramic material used as quartz generates bleaching phenomenonDielectric life guaranteedfor more than 2 years as it uses dozens times lower voltage then breakdown voltageElectrode should be replaced every year as high-voltage insulation fatigue strength increases over time Realize long life of the reactor electrodes Lower maintenance / management costs