The Difference of APP Plasma Technology

1. Direct plasma guarantees faster, better treatments.

2. Lower gas consumptions means lower costs.

AR vs N2

7.000 Liter x 5EA
Gas consumption per month, Standard 100mm

  1. Length of the plasma head: 200mm
  2. Conversion rate (Liquid/Gas)
    1. Ar Gas: 1L / 840L
    2. N2 Gas: 1L / 700L
  3. 3. Cost per litre (quote from Supplier P)
  4. Time of operation per month: 6000 minutes (60 minutes * 20 hours * 30 days / 6, 6 = 30 seconds / 5 seconds)

3. No suction system is required because the side production level of noxious gases (ozone, NOx) is near zero.

* Performance test Model : MD-150 (3Kit)

1) Test for ozone production

Test itemSTANDARDResult
8hours averageMust be less than 0.04 ppm 0,008 ppm
MaximumMust be less than 0.04 ppm 0,012 ppm

2) Test for NOx production

Test itemSTANDARDResult
8 hours averageMust be less than 0.04 ppm 0,02 ppm
MaximumMust be less than 0.04 ppm 0,02 ppm

4. No effect of surface treatment except plasma contact

Plasma treatment surface
(Front)
① : Dyne(60) Test result:
Ink spreads on the surface
Contact angle 10.7˚
Plasma treatment surface
(Backside)
② : Dyne(60) Testresult:
Ink gets together
④ : Contact angle 42.6˚

◎ Working Distance : 6mm
◎ Treatment Speed : 60mm/sec

5. No Particle

*Model : MD-200
Particle measurement results

 

Plasma Type (Company)

Experimental conditions

No of particles seeds

(0.3 um↑/minutes)

Remark

Ar Plasma 

(APP)

Plasma “Off”

Gas (Ar) “On”

1.5

Plasma “On”

Gas (Ar) “On”

3.5

1.5 → 3.5 (2increased)

He Plasma

(APP)

Plasma “Off”

Gas (He) “On”

2.2

Plasma “On”

Gas (He) “On”

1.8

2.2 → 1.8 (no increase)

N2 Plasma

Other company

Plasma “Off”

Gas (N2+CDA) “On”

14

Plasma “On”

Gas (N2+CDA) “On”

408

14 → 408 (394increased)

6. Superior performance in removing static electricity

Before plasma treatment

After plasma treatment

  • Removing static electricity through module itself ground
  • Hundreds times of removing effect more than Ionizer

7. Safe and power consumption reduction using low-voltage plasma

  • 1/10 compared to other companies

8. Excellent durability

Low Voltage (Direct Plasma) - APP

High voltage (Remote plasma) 

Small sputtering phenomenon by small ion acceleration

Big ion acceleration and particle generated because of sputtering phenomenon

Bo bleaching for quartz and general ceramics

Special ceramic material used as quartz generates bleaching phenomenon

Dielectric life guaranteedfor more than 2 years as it uses dozens times lower voltage then breakdown voltage

Electrode should be replaced every year as high-voltage insulation fatigue strength increases over time

  • Realize long life of the reactor electrodes
  • Lower maintenance / management costs